Hi, there seems to typo in _qiv completion : - '(-c --contrast)'{-b,--contrast}'[set contrast]:contrast (-32..32)' \ and - '(-g --gamma)'{-b,--gamma}'[set gamma]:gamma (-32..32)' \ from my manual -c and -g are the rights options for contrast and gamma respectively. I join a correction suggestion arno. --- _qiv 2006-11-24 05:37:22.000000000 +0100 +++ _qiv~ 2007-01-02 19:19:15.000000000 +0100 @@ -14,8 +14,8 @@ '(-m --maxpect)'{-m,--maxpect}'[expand image to fit screen size]' \ '(-t --scale_down)'{-t,--scale_down}'[shrink images to fit screen size]' \ '(-b --brightness)'{-b,--brightness}'[set brightness]:brightness (-32..32)' \ - '(-c --contrast)'{-b,--contrast}'[set contrast]:contrast (-32..32)' \ - '(-g --gamma)'{-b,--gamma}'[set gamma]:gamma (-32..32)' \ + '(-c --contrast)'{-c,--contrast}'[set contrast]:contrast (-32..32)' \ + '(-g --gamma)'{-g,--gamma}'[set gamma]:gamma (-32..32)' \ '(-n --no_filter)'{-n,--no_filter}'[disable filtering of images by extension]' \ '(-i --no_statusbar -I --statusbar)'{-i,--no_statusbar}'[disable statusbar]' \ '(-i --no_statusbar -I --statusbar)'{-I,--statusbar}'[enable statusbar]' \
Attachment:
signature.asc
Description: Digital signature